Ultra-Small DC Coupled Detector Log Amplifier (ERDLA)

ERDLA1826-C
Specifications
Frequency Range 18 – 26 GHz

To meet the following Environmental Conditions:

Operating Case Temp: -40 to +85°C

Storage Temp:            -54 to +105°C

Mechanical Shock:
Per MIL-STD-810F, Method 516.5

Vibration:
Per MIL-STD-810F, Method 514.5

Humidity:
Per MIL-STD-810F, Method 507.4

Material:  SS303

Finish:
Gold Plating per MIL-G-45204B

Dynamic Range -65 – +5 dBm
TSS -67 dBm
Input VSWR 2.5:1 typical
Rise Time 15 nsec. typical
20 nsec. max.
Recovery Time 300 nsec. max.
Log Accuracy ±1.8 dB max.
Log Linearity ±1.3 dB max.
Log Slope 50±4 mV/dB
(25 to 100 mV/dB opt.)
Output DC Offset
(without input signal)
+100±100 mV
(-100 to +400 mV opt.)
Output Load Impedance
(Output short circuit protected)
100 Ohms ±2 Ohms
Maximum Input Power +15 dBm min.
Power Supply +12 to +15V @350 mAmp max.
-12 to -15V @100 mAmp max.
Scroll to Top

Request For Quotation

Get a free quote for your electronic components. Fill out the form with your specs and contact info, and our experts will provide customized solutions. We’re dedicated to quality and service. Contact us now!